missing translation for 'onlineSavingsMsg'
Learn More

Sartorius Sterisart™ NF Sterility Testing System
BIOPHARMA

Codice prodotto. 11730965 Sfoglia Tutto Sartorius Prodotti
Cambia vista
Click to view available options
Metodo di sterilizzazione:
Gamma Irradiation
Include:
Long dual-needle spike, sterile vented
Long dual-needle spike, sterile vented, septum
Long needle, by-packed sterile venting needle
Long needle, sterile venting needle, septum
Short dual-needle spike, sterile vented, with septum
Tubing system w/ two dual-needle metal spikes of different length
Universal Luer adapter, long dual-needle spike, sterile vented, septum
Dimensione della confezione:
pezzi 10
7 product options available for selection
Product selection table with 7 available options. Use arrow keys to navigate and Enter or Space to select.
Codice prodotto. Metodo di sterilizzazione Include Dimensione della confezione
11730965 Gamma Irradiation Long needle, sterile venting needle, septum pezzi 10
11700965 Gamma Irradiation Long dual-needle spike, sterile vented, septum pezzi 10
11790955 Gamma Irradiation Long dual-needle spike, sterile vented pezzi 10
11720965 Gamma Irradiation Long needle, by-packed sterile venting needle pezzi 10
11770965 Gamma Irradiation Tubing system w/ two dual-needle metal spikes of different length pezzi 10
15972530 Gamma Irradiation Short dual-needle spike, sterile vented, with septum pezzi 10
11760965 Gamma Irradiation Universal Luer adapter, long dual-needle spike, sterile vented, septum pezzi 10
Use arrow keys to navigate between rows. Press Enter or Space to select a product option. 7 options available.
7 options
This item is not returnable. View return policy
Product Code. 11730965 Supplier Sartorius Supplier No. 16467GSD
  • ONLINE EXCLUSIVE PRICE
    787.00 CHF
    592.73 CHF / 10 Stück
    Sparen 194.27 CHF
    24% Rabatt
 Articolo soggetto a restrizioni
Lager vorrätig
Add to basket
Add to basket

missing translation for 'validMainframeMsg'

This item is not returnable. View return policy

Provides completely closed system sterility testing of pharmaceuticals, open containers, closed containers, pre-filled syringes, powders, and medical devices. Sartorius Sterisart™ NF Sterility Testing System is optimal for use with isolators.

International pharmacopoeias require the complete sterility of pharmaceutical products that are injected into the blood stream or that otherwise enter the body below the skin surface. As a manufacturer of such products, you are required to supply proof of sterility of the final product batch. Sterisart™ NF is a completely closed system for the sterility testing of pharmaceutical products. It is based on the membrane filter method, however it eliminates the procedure of manipulating the filters. By this the main risk of a secondary contamination and false positive results is eliminated. A peristaltic pump transfers the sample into the filtration units, and after rinsing, the filtration units are filled with media and used for incubation of the filters without any contact to the environment.

  • reliable Sartochem™ membrane
  • high retention of microbes
  • low adsorption
  • high mechanical stability
  • pre-installed color-coded tube clamps
  • easy-to-read graduated marks
  • user-friendly (several practical adapters available)
  • product-/lot number identification
  • gas-impermeable packaging for protection against sterilants
TRUSTED_SUSTAINABILITY

Specifications

Particle Retention 0.45 μm
Dimensione del poro 0.45 μm
Sterilità Sterile
Area di filtraggio 15.7 cm
Da utilizzare con (applicazione) Sterility Testing
Include Long needle, sterile venting needle, septum
Pressione max 3 bar at 20°C
Tipo di campione LVPs, SVPs
Metodo di sterilizzazione Gamma Irradiation
Temperatura (sistema imperiale) max 122°F
Temperatura (sistema metrico) max 50°C
Tipo Sterisart System
Volume (sistema imperiale) 4 oz.
Volume (sistema metrico) 120 mL
Tipo di chiusura Septum
Show More Show Less
Product Title
Select an issue

By clicking Submit, you acknowledge that you may be contacted by Fisher Scientific in regards to the feedback you have provided in this form. We will not share your information for any other purposes. All contact information provided shall also be maintained in accordance with our Privacy Policy.