missing translation for 'onlineSavingsMsg'
Learn More

Thermo Scientific™ POROS™ CaptureSelect™ FSH Affinity HPLC Columns

Artikelnummer. 18416428 Alle ansehen Thermo Scientific Produkte
Ansicht ändern
Click to view available options
Länge (metrisch):
30 mm
50 mm
100 mm
Durchmesser (metrisch):
2.1 mm
4.6 mm
Packungsgröße:
1 Stück
3 product options available for selection
Product selection table with 3 available options. Use arrow keys to navigate and Enter or Space to select.
Artikelnummer. Länge (metrisch) Durchmesser (metrisch) Packungsgröße
18416428 30 mm 2.1 mm 1 Stück
18496558 50 mm 4.6 mm 1 Stück
18466648 100 mm 4.6 mm 1 Stück
Use arrow keys to navigate between rows. Press Enter or Space to select a product option. 3 options available.
3 options
Dieser Artikel kann nicht zurückgegeben werden. Rückgaberichtlinie anzeigen
Artikelnummer. 18416428 Lieferant Thermo Scientific™ Lieferanten-Nr. 4481822
  • ONLINE EXCLUSIVE PRICE
    4695.00 CHF
    4155.00 CHF / 1 Stück
    Sparen 540.00 CHF
    11% Rabatt
 Eingeschränkter Artikel
Lager vorrätig
Zum Warenkorb hinzufügen
Zum Warenkorb hinzufügen

missing translation for 'validMainframeMsg'

Dieser Artikel kann nicht zurückgegeben werden. Rückgaberichtlinie anzeigen

Analytical teams that support biologic drug development require rapid, sensitive, and precise methods for protein quantitation from cell culture, fermentations broths, or purification intermediates.

Analytical teams that support biologic drug development require rapid, sensitive, and precise methods for protein quantitation from cell culture, fermentations broths, or purification intermediates. It is critical for biopharmaceutical manufacturers to be able to monitor bioreactor product titers to determine when to harvest or abort a reactor cycle. POROS CaptureSelect FSH HPLC columns incorporate the advantages of high-speed POROS chromatography resins with the unique selectivity of CaptureSelect ligands, enabling 3-minute quantitation of human follicle stimulating hormone (FSH).

Features of this class of chromotography columns:

  • Broad utility—POROS A, G, and CaptureSelect affinity ligands address most biological drug classes
  • Rapid—POROS resins offer fast quantitation or purification of immunoglobulins and fusion proteins
  • Hands-off operation—HPLC method can be automated for streamlined operation
  • Robust—delivers high-performance purification over hundreds of chromatography cycles

High Speed with High Specificity

The combination of CaptureSelect FSH affinity ligand with POROS 20 μm resin provides a high flow-rate, high performance chromatography solution for the rapid quantitation and small-scale purification of FSH.

POROS high performance chromatography allows for the quantitation of product from clarified harvest or partially purified intermediates—typically in less than 3 minutes. Moreover, only minimal sample preparation (0.2 μm filtration) is required, and the eluted product is highly purified and suitable for further analysis, including mass spectrometry.

Automation

POROS affinity chromatography columns are suitable for use with HPLC systems, allowing for the automation of chromatography, data collection, and data analysis. In addition, the immobilized affinity ligands enable one method and buffer system to be used across a class of molecules, streamlining analytical approaches.

Multiple Cycles

Proper sample preparation, adherence to column operating instructions, and the use of an optimized column cleaning regime results in strong re-use performance. POROS affinity chromatography columns can be cycled hundreds of times for cost-effective and reproducible quantitation or purification.

TRUSTED_SUSTAINABILITY

Spezifikation

Durchmesser (metrisch) 2.1 mm
Enthält Column includes EZ grip fittings and column test certificate.
Länge (metrisch) 30 mm
Max. Druck 180 bar
Partikelgröße 20 μm
Porengröße 2000 Å
Menge 1 Säule
Stationäre Phase Follicle Stimulating Hormone affinity ligand, humanspecific
Produktlinie CaptureSelect, POROS
Bindungsvermögen 1.5 mg/mL resin
Max. Elutionsvolumen <100 μL
Hochdurchsatz-Kompatibilität Automated Protocols
Probentyp Biopharmaceutical Purification Sample, Bulk Drug Substance Sample, Cell Cultures
Zielmolekül Follicle Stimulating Hormone
Volumen (metrisch) 0.1 mL
Säulentyp Affinity
Phase Affinity Separation
Material PEEK
Aufreinigungsziel Follicle Stimulating Hormone
Verfahren Antibody Affinity Chromatography
Zur Verwendung mit (Anwendung) FPLC
Produkttyp Säule
Mehr anzeigen Weniger anzeigen

For Research Use Only. Not for use in diagnostic procedures.

Name des Produkts
Wählen Sie ein Thema

Indem Sie auf Absenden klicken, erklären Sie sich damit einverstanden, dass Fisher Scientific sich mit Ihnen in Verbindung setzen kann, um Ihr Feedback in diesem Formular zu bearbeiten. Wir werden Ihre Informationen nicht für andere Zwecke weitergeben. Alle bereitgestellten Kontaktinformationen werden in Übereinstimmung mit unserer Datenschutzrichtlinie aufbewahrt. Datenschutzrichtlinie.