Thermo Scientific™ Orion™ Nitrate Ion Selective Electrodes
Descrizione
Measure nitrate in aqueous solutions simply, accurately and economically with Thermo Scientific™ Orion™ Nitrate Electrodes.
The ThermoFisher Orion Nitrate electrode complies with SM 4500-NO3 - D; Orion Method 601 for Drinking water and SM 4500-NO3 - D for Wastewater measurements.
Features:
- 9707BNWP is a combination electrode with a Sure-Flow™ junction. When conventional electrode junctions clog, the Sure-Flow junction can be opened and flushed clean simply by pressing the cap. To be used with module 970701.
- Nitrate Half-Cell Electrode 9307BNWP (comes with half cell module 930702) is to be used with the Orion 900200 sure flow double junction reference electrode.
Solutions required:
- Standards
- 920706 0.1 M NaNO3 nitrate calibration standard
- 920707 1000 ppm as N nitrate calibration standard
- 930707 100 ppm as N nitrate calibration standard
- ISA
- 930711 ISA for nitrate measurements, 475 mL bottle
- 930710 Nitrate interference suppressor solution (NISS), 475 mL bottle
- Electrode fill solution
- 900046 Optimum Results F electrode filling solution, 5 x 60 mL bottles
- 900002 Inner chamber filling solution for the double junction reference electrode, 5 x 60 mL bottles
Items included with:
- 9307BNWP
- 930702 93 series sensing module for 9307BNWP. Quantity 2
- 930711 ISA for nitrate measurements. 60mL 1 bottle
- 9707BNWP
- 970701 97 series sensing module for 9707BNWP. Quantity 2
- 900046 ISA for nitrate measurements. 60mL 1 bottle
Warranty period:
- Electrode: 12 months from date of purchase
- Module: 6 months from date of purchase and 3 months once in operation
Specifica
Specifica
| Applicazioni | Water testing, soil, soil extracts and saturated paste, plants and forage, animal feed |
| Tipi di connettore | None |
| Descrizione | Modulo di ricambio per elettrodo a semicella per nitrati 9307BNWP; 3/confezione |
| Deriva | potenziali senza deriva |
| Giunzione | La giunzione a flusso libero Sure-Flow™ assicura una stabile |
| Materiale | Plastic |
| Certificazione/Conformità | 4500-NO3 D, Orion Method 601, EPA SW-846 9210A, AOAC986.31 |
| Da utilizzare con (apparecchiatura) | Misuratori ISE |
| Temperatura (sistema metrico) operativa | 0°C to 40°C |
| Tipo | Elettrodo ionoselettivo combinato |
Facendo clic su Invia, l'utente riconosce che potrebbe essere contattato da Fisher Scientific in merito al feedback fornito in questo modulo. Non condivideremo le vostre informazioni per altri scopi. Tutte le informazioni di contatto fornite saranno conservate in conformità con la nostra Politica sulla privacy. Informativa sulla privacy.