missing translation for 'onlineSavingsMsg'
Learn More

Invitrogen™ No-Stain™ Protein Labeling Reagent

Codice prodotto. 16341358
Cambia vista
Click to view available options
N. di reazioni:
10 reactions
40 reactions
Gel Compatibility:
Any Gel Type and Gel Chemistry
Dimensione della confezione:
10 reazioni
40 reazioni
2 product options available for selection
Product selection table with 2 available options. Use arrow keys to navigate and Enter or Space to select.
Codice prodotto. N. di reazioni Gel Compatibility Dimensione della confezione
16341358 40 reactions Any Gel Type and Gel Chemistry 40 reazioni
16351358 10 reactions Any Gel Type and Gel Chemistry 10 reazioni
Use arrow keys to navigate between rows. Press Enter or Space to select a product option. 2 options available.
2 options
Les retours ne sont pas autorisés pour ce produit. Consulta la politica di reso
Codice prodotto. 16341358 Fornitore Invitrogen™ N. del fornitore A44449
  • ONLINE EXCLUSIVE PRICE
    211.00 CHF
    189.65 CHF / 40 Reaktionen
    Sparen 21.35 CHF
    10% Rabatt
Visualizza tutte le promozioni
 Articolo soggetto a restrizioni
Lager vorrätig
Aggiungi al carrello
Aggiungi al carrello

missing translation for 'validMainframeMsg'

Les retours ne sont pas autorisés pour ce produit. Consulta la politica di reso

A fast, easy to use, covalent protein labeling reagent, applied to a membrane after gel transfer that provides sensitive, linear detection of protein for total protein normalization of western blotting data. The Invitrogen No-Stain Reagent can also be used as a fast, sensitive gel stain for visualization of proteins in a gel.

The Invitrogen No-Stain Protein Labeling Reagent provides a flexible, accurate, rapid, and reliable method to visualize and normalize proteins in a gel or on a membrane (post-transfer). It forms covalent bonds to proteins in gels or on membranes within 10 minutes, does not require any de-staining steps, and can be instantly visualized using any commonly available imager. No-Stain reagent does not require any particular gels or other reagents and is compatible with gel stains and western workflows.

Instant visualization of proteins in gels

Coomassie and other gel staining and de-staining steps can be extremely time consuming and cumbersome. No-Stain Protein Labeling Reagent forms covalent bonds with the lysine amino acid side chains on all proteins in a gel within 10 minutes. Since lysine is one of the most abundant amino acids, No-Stain reagent enables detection of all proteins in a gel or on a membrane, and the strong signal emission from the covalently bonded reagent provides nanogram-level sensitivity.

  • Alternative to traditional gel staining reagents—provides more accurate normalization over a wide range of protein lysate concentrations (1–80 μg)
  • Sensitive—lower limit of detection of 20 ng per band
  • Specific—forms bonds only with the lysine side chains of proteins. Unbound reagent does not emit, thereby enabling a superior signal-to-noise ratio
  • Flexible—no need to change your gels to get stain-free convenience. No-Stain reagent provides stain-free convenience with any gel type (precast or pour-your-own gel)

Achieve the gold standard for quantitative western blotting

Protein normalization is a critical step in obtaining reliable and reproducible quantitative western blotting. Total protein normalization is considered the gold standard for quantitative western blotting. Many leading journals have developed guidelines for submitting western blotting research and select quotes from those guidelines are provided below.

  • 'For quantitative comparisons, appropriate reagents, controls and imaging methods with linear signal ranges should be used' – Nature
  • 'Record how data were obtained, whether signal intensity was linear with antigen loading, and how protein loading was normalized' – Journal of Biological Chemistry
  • 'Normalize signal intensity to total protein loading (assessed by staining membranes for total protein) whenever possible' – Journal of Biological Chemistry
  • 'House-keeping proteins should not be used for normalization without evidence that manipulations do not affect expression' – Journal of Biological Chemistry

An accurate loading control should display a linear relationship between signal intensity and sample load in all experimental conditions. The signal intensity obtained from labeling of total proteins on a membrane with No-Stain reagent ensures a linear relationship between signal intensity and sample load (see figure below) in all experimental conditions. Therefore, the use of No-Stain reagent in quantitative western blot applications enables the use of total protein as an ideal loading control.

  • Easy-to-use protocol—labeling of proteins within 10 minutes on either nitrocellulose or PVDF membranes
  • Rapid visualization using a wide-range of imagers with UV or fluorescence light sources
  • Accurate total protein normalization—the broad linear range for protein detection of 1–80 μg enables detection of No-Stain signal along with that of your target protein to achieve accurate total protein normalization
  • Sensitive and stable—nanogram level sensitivity with a stable signal that is compatible with downstream immunodetection steps
  • Superior analysis—housekeeping proteins are susceptible to signal saturation and other biological variations which are not observed when using No-Stain reagent for total protein normalization

Learn more about No-Stain Protein Labeling Reagent ›

TRUSTED_SUSTAINABILITY

Especificaciones

Product Type Protein Labeling Reagent
Content And Storage • No-Stain activator, 800 μL, store at -20°C
• No-Stain derivatizer, 800 μL, store at -20°C
• No-Stain labeling buffer (20X), 2 x 20 mL, store at 15°C to 30°C
Descrizione The No-Stain Protein Labeling Reagent forms covalent bonds with the lysine amino acid side chains on all proteins
Da utilizzare con (apparecchiatura) Compatible with wide-range of imagers with UV or Fluorescence light sources, for example, the iBright imager
N. di reazioni 40 reactions
Run Time 10 minutes
Shipping Condition Dry Ice
Metodo di rilevamento Chemiluminescence, Fluorescence
Gel Compatibility Any Gel Type and Gel Chemistry
Membrane Compatibility Nitrocellulose, PVDF
Product Line Invitrogen
Quantità 1 kit
Da utilizzare con (applicazione) Compatible with all downstream immunodetection steps (blocking, antibody binding, chemiluminescent or fluorescence based detection
Mostrar más Mostrar menos
compliance-icons
Nombre del producto
  • 40RXN No-Stain Protein Labelling Reagent
Palabra de advertencia
  • Attenzione
Clasificación
  • Lesione oculare grave/irritazione oculare Categoria 2
Indicaciones de peligro
  • H319-Provoca grave irritazione oculare.
Consejos de prudencia
  • P210-Tenere lontano da fonti di calore, superfici riscaldate, scintille, fiamme e altre fonti di innesco. Vietato fumare.
  • P264-Lavare accuratamente dopo l'uso.
  • P280-Indossare guanti/indumenti protettivi/Proteggere gli occhi/il viso.
  • P305+P351+P338-IN CASO DI CONTATTO CON GLI OCCHI: sciacquare accuratamente per parecchi minuti. Togliere le eventuali lenti a contatto se è agevole farlo. Continuare a sciacquare.
  • P332+P313-In caso di irritazione della pelle: consultare un medico.
  • P337+P313-Se l'irritazione degli occhi persiste, consultare un medico.
  • P370+P378-In caso d'incendio: utilizzare per estinguere.
  • P403-Conservare in luogo ben ventilato.
  • P501b-Smaltire il prodotto/recipiente in conformità con le disposizioni locali/regionali/nazionali/internazionali.
Otros peligros
  • MIXTURE LIST-Contain: Mandelonitrile, DMSO

For Research Use Only. Not for use in diagnostic procedures.

Título del producto
Seleccione un problema

Al hacer clic en Enviar, acepta que Fisher Scientific se ponga en contacto con usted en relación con los comentarios que ha proporcionado en este formulario. No compartiremos su información para ningún otro fin. Toda la información de contacto proporcionada se mantendrá de acuerdo con nuestra Política de Privacidad. Política de privacidad.