Thermo Scientific™ MAbPac™ SCX-10 HPLC Columns
BIOPHARMA

Codice prodotto. 12683085
Cambia vista
Click to view available options
Lunghezza (sistema metrico):
50 mm
150 mm
250 mm
Diametro (sistema metrico):
2 mm
4 mm
4.6 mm
9 mm
Dimensione particelle:
3 μm
5 μm
5 µm
10 μm
10 µm
Formato colonna:
Colonna analitica
Guard Column
Preparative Column
Dimensione della confezione:
Pezzo
14 product options available for selection
Product selection table with 14 available options. Use arrow keys to navigate and Enter or Space to select.
Codice prodotto. Lunghezza (sistema metrico) Diametro (sistema metrico) Dimensione particelle Formato colonna Dimensione della confezione
12683085 250 mm 4 mm 5 µm Colonna analitica Pezzo
11372063 250 mm 4 mm 10 µm Colonna analitica Pezzo
11332083 150 mm 4 mm 10 μm Colonna analitica Pezzo
11342083 50 mm 4 mm 10 μm Colonna analitica Pezzo
11391993 250 mm 2 mm 10 μm Colonna analitica Pezzo
15540244 250 mm 9 mm 10 μm Preparative Column Pezzo
15124725 150 mm 4 mm 5 μm Colonna analitica Pezzo
15134725 50 mm 4.6 mm 5 μm Colonna analitica Pezzo
15154725 150 mm 4.6 mm 5 μm Colonna analitica Pezzo
15144725 250 mm 4.6 mm 5 μm Colonna analitica Pezzo
12663085 50 mm 4 mm 3 μm Colonna analitica Pezzo
12673085 50 mm 4 mm 5 μm Colonna analitica Pezzo
11382023 50 mm 2 mm 10 μm Guard Column Pezzo
11362063 50 mm 4 mm 10 μm Guard Column Pezzo
Use arrow keys to navigate between rows. Press Enter or Space to select a product option. 14 options available.
14 options
This item is not returnable. View return policy
Product Code. 12683085 Supplier Thermo Scientific™ Supplier No. 078655
 Articolo soggetto a restrizioni
Edge
Attualmente non disponibile: Non abbiamo informazioni su quando questo prodotto sarà disponibile.
View alternative products

missing translation for 'validMainframeMsg'

This item is not returnable. View return policy

Use these strong cation-exchange columns for high-resolution, high efficiency analysis of monoclonal antibodies (mAbs) and associated variants.

Use Thermo Scientific™ MAbPac™ SCX-10 LC Columns for high-resolution, high efficiency analysis of monoclonal antibodies (mAbs) and associated variants. The unique nonporous pellicular resin provides the resolving power to separate mAb variants that differ by as little as one charged residue. A hydrophilic layer surrounds the polymeric beads and eliminates hydrophobic interactions with the resin, resulting in very efficient peaks. A proprietary grafted cation-exchange surface provides pH selectivity control for high-resolution separations.

Superior Performance for mAb Variant Analysis
  • Exceptionally high resolution for mAb variants
  • Ideal for characterization and quality control assessment of mAbs
  • Well-suited for stability studies, mAb therapeutic method development and high-throughput screening
  •  Unmatched column-to-column and lot-to-lot reproducibility eliminates column variability as a concern in stability and QA/QC testing
  • Meets the regulatory requirements for biopharmaceutical characterization
Multiple Sizes Available
  • Available in 3, 5 and 10μm particle sizes in standard and UHPLC formats
  • Smaller-particle-size columns provide the same resolution as the 10μm columns, but with significantly faster analysis time
TRUSTED_SUSTAINABILITY

Specifications

Formato colonna Colonna analitica
Diametro (sistema metrico) 4 mm
Portata 0.5 mL/min
Lunghezza (sistema metrico) 250 mm
Pressione max 5000 psi
Dimensione particelle 5 µm
pH Da 2 a 12
Dimensione del poro Non poroso
Quantità Each
Solventi 50% Acetonitrile
Temperatura 60 °C
Fase stazionaria Solfonato
Product Line MAbPac
Materiale di impaccamento Polimero non poroso, sferico
Tipo di colonna Scambio ionico
Fase Ion Exchange
Materiale PEEK
Tecnica Bio-LC
Green Features FSC
Product Type Colonna analitica
Show More Show Less

Limited warranty period: Subject to all warranty requirements and exclusions set out in our Terms and Conditions of Sale, this product is warranted from the date we ship the product and for ninety (90) days thereafter. Disclaimer to internal research use restriction: Any restrictions on the purchaser to utilize the product(s) for internal research purposes only does not apply to the product(s) on the web pages associated with this statement.