missing translation for 'onlineSavingsMsg'
Learn More

Invitrogen™ Luminex™ FLEXMAP 3D™ Instrument System

Codice prodotto. 30245342
Cambia vista
Click to view available options
Quantità:
1 system
Dimensione della confezione:
Pezzo
1 product options available for selection
Product selection table with 1 available options. Use arrow keys to navigate and Enter or Space to select.
Codice prodotto. Quantità Dimensione della confezione
30245342 1 system Pezzo
Use arrow keys to navigate between rows. Press Enter or Space to select a product option. 1 options available.
1 options
Les retours ne sont pas autorisés pour ce produit. Consulta la politica di reso
Codice prodotto. 30245342 Fornitore Invitrogen™ N. del fornitore APX1342
 Articolo soggetto a restrizioni

Questo articolo richiede un aggiornamento del prezzo prima di essere ordinato.

Richiedi qui il prezzo per questo articolo.

missing translation for 'validMainframeMsg'

Les retours ne sont pas autorisés pour ce produit. Consulta la politica di reso

The Luminex FLEXMAP 3D Instrument System is the most advanced and versatile multiplexing platform with a fast read time, compatibility with both 96- and 384-well plates, and ease of integration with front-end automation systems.

The Luminex FLEXMAP 3D Instrument System is the most advanced and versatile multiplexing platform. A fast read time, compatibility with both 96- and 384-well plates, and ease of integration with front-end automation systems make the Luminex FLEXMAP 3D system the platform of choice for high-throughput applications. Automated start up, shut down, and maintenance routines make the Luminex FLEXMAP 3D system easy to use and maintain. The system is compatible with ProcartaPlex multiplex immunoassays and QuantiGene Plex multiplex gene expression assays.

Features of the Luminex system include:

  • Multiplexing: up to 500 analytes in a single sample
  • Dynamic range (typical): ≥4.5 logs
  • Read time: 96-well plate in ∼20 min (up to 144,000 tests/hour); 384-well plate in ∼75 min (up to 153,600 tests/hour)
  • Daily start-up/shut-down: ≤30 min

Available options

  • Software: extra seat licenses, Basic Security Module, 21 CFR part 11 Module, Automation Module, LIS/LIMS Module
  • Service: service contracts, IQ/OQ

Luminex xMAP technology

The open architecture of Luminex xMAP technology uses imaging, microspheres, digital signal processing, and traditional chemistry—combining proven technologies in a unique way.

Advantages of Luminex xMAP technology include:

  • Helps reduce costs and labor through multiplexing
  • Smaller sample size requirements compared to single result assays
  • Enables fast, reproducible results from favorable kinetics of liquid bead array approach
  • Broad coverage of applications, including protein expression and gene expression profiling

How Luminex xMAP technology works

Sets of magnetic microspheres are color-coded with combinations of red and infrared fluorophores. Each bead set is coated with a reagent specific to a particular bioassay, allowing the capture and detection of several specific analytes from a single sample. Optics in the compact analyzer excite the internal dyes that identify each microsphere as well as any reporter dye captured, providing quantitation of individual analytes on each microsphere. The analyzer reads many beads from each set, enabling rapid and precise results for several targets within a single sample.

TRUSTED_SUSTAINABILITY

Specifica

Content And Storage • FLEXMAP 3D instrument
• xMAP Sheath Fluid
• Sample Probe-Needle
• Off Plate Reagent Block
• Waste Container
• Barcode Scanner
• Heater Block (96-well plate)
• Heater Block (384-well plate)
• Documentation
• Desktop PC with Windows 10; Dell monitor, keyboard, and mouse; xPONENT Software (3 seats), and 90-day trial of Security, 21 CFR Part 11, Automation and LIS modules
• Sample Probe Height Adjustment Tool

Shipped separately:
• FLEXMAP 3D Calibration Kit
• FLEXMAP 3D Performance Verification Kit

Formato 96- or 384-well Plate
Linea di prodotti Luminex, FLEXMAP 3D
Shipping Condition Room Temperature
Quantità 1 system

For Research Use Only. Not for use in diagnostic procedures.

Titolo del prodotto
Selezionare un problema

Facendo clic su Invia, l'utente riconosce che potrebbe essere contattato da Fisher Scientific in merito al feedback fornito in questo modulo. Non condivideremo le vostre informazioni per altri scopi. Tutte le informazioni di contatto fornite saranno conservate in conformità con la nostra Politica sulla privacy. Informativa sulla privacy.