Invitrogen™ LIVE/DEAD™ Fixable Violet Dead Cell Stain Kit, for 405 nm excitation
Descrizione
The LIVE/DEAD™ Fixable Violet Dead Cell Stain Kit is used to determine the viability of cells prior to the fixation and permeabilization required for intracellular antibody staining or prior to elimination of biohazardous materials using formaldehyde fixation. This kit has been optimized and validated for use with a violet laser flow cytometer.
- Stable—dyes are freeze dried in separate vials to maintain stability
- Robust—staining pattern is the same before and after fixation
- Low compensation—minimal spectral overlap between other fluorophores
Stable
The product is sold in tubes with DMSO and in lyophilized flow tubes and plates which require no DMSO. Amine reactive dyes in solution will lose their effectiveness over a short period of time, therefore it is recommended to completely use material once rehydrated.
Robust
Dead cell discriminator stains can lose sensitivity after treatment with fixatives such as formaldehyde or ethanol-based fixation methods required for intracellular phosphorylation studies. The LIVE/DEAD™ Fixable Violet Stain is an amine reactive dye that binds covalently to intracellular and extracellular amines, and the staining pattern is preserved following formaldehyde fixation.
Low compensation
The LIVE/DEAD™ Fixable Violet Stain was selected based on its fluorescent properties to minimize compensation between other violet dyes and dyes that excite off of the 488 nm blue laser. The violet-fluorescent reactive dye has an excitation maximum of ∼416 nm and is excited well with the 405 nm violet laser, and it has an emission maxima of ∼451 nm, so it can be collected in the first channel on most violet laser flow cytometers.
How it works
In cells with compromised membranes, the dye reacts with free amines both in the cell interior and on the cell surface, yielding intense fluorescent staining. In viable cells, the dye's reactivity is restricted to the cell-surface amines, resulting in less intense fluorescence. The difference in intensity is typically greater than 50-fold between live and dead cells, allowing for easy discrimination.
Colors available
LIVE/DEAD™ Fixable Dead Cell Stains are available in a wide variety of colors to meet your multi-color panel needs.
Specifica
Specifica
| Permeabilità celle | Impermeant |
| Tipo di cellula | Eukaryotic Cells |
| Colore | Violet |
| Content And Storage | Contains 10 vials of LIVE/DEAD™ fixable dead cell stain and 500 μL DMSO. Store at -20°C. |
| Descrizione | LIVE/DEAD™ Fixable Violet Dead Cell Stain Kit, for 405 nm excitation |
| Metodo di rilevamento | Fluorescence |
| Da utilizzare con (applicazione) | Viability Assay |
| Da utilizzare con (apparecchiatura) | Flow Cytometer |
| Product Type | Stain |
| Tipo di colorante | LIVE/DEAD™ Fixable Violet Dead Cell Stain |
| Vedi altri risultati |
For Research Use Only. Not for use in diagnostic procedures.
Facendo clic su Invia, l'utente riconosce che potrebbe essere contattato da Fisher Scientific in merito al feedback fornito in questo modulo. Non condivideremo le vostre informazioni per altri scopi. Tutte le informazioni di contatto fornite saranno conservate in conformità con la nostra Politica sulla privacy. Informativa sulla privacy.