Thermo Scientific™ Micro kit per estrazione da gel e purificazione DNA GeneJET™
Sfoglia Tutto Thermo Scientific ProdottiDescription
The kit combines the convenience of spin column technology with the selective binding properties of a silica membrane, eliminating the need for tedious resin manipulations or toxic phenol-chloroform extractions.
The GeneJET Gel Extraction and DNA Cleanup Micro Kit effectively removes primers, primer dimers, dNTPs, unincorporated labeled nucleotides, enzymes and salts from PCR and other reaction mixtures. The kit can be used for purification of DNA fragments from 100 bp to 20 kb. The recovery rates are 90 to 100% for 100 bp to 3 kb DNA fragment size range. Each GeneJET DNA Purification Column has a total binding capacity of up to 10 μg of DNA, and the entire procedure takes approximately 3.5 minutes for DNA cleanup
Thermo Scientific GeneJET Gel Extraction and DNA Cleanup Micro Kit is developed as 3 in 1 kit designed for rapid and efficient purification of DNA from PCR, enzymatic reaction mixtures, and DNA extraction from standard or low-melting point agarose gels run in either Tris acetate (TAE) or Tris borate (TBE) buffer. The kit combines the convenience of spin column technology with the selective binding properties of a silica membrane, eliminating the need for tedious resin manipulations or toxic phenol-chloroform extractions.
The GeneJET Gel Extraction and DNA Cleanup Micro Kit effectively removes primers, primer dimers, dNTPs, unincorporated labeled nucleotides, enzymes and salts from PCR and other reaction mixtures. The kit can be used for purification of DNA fragments from 100 bp to 20 kb. The recovery rates are 90 to 100% for 100 bp to 3 kb DNA fragment size range. Each GeneJET DNA Purification Column has a total binding capacity of up to 10 μg of DNA, and the entire procedure takes approximately 3.5 minutes for DNA cleanup
Highlights
• Advanced column design—easy to open, load and handle
• Yields concentrated DNA - Elute in 6 to 10 μL volume
• High recovery - 90 to 100% recovery in the 100 to 3000 bp DNA fragment range
• Fast—4 minute reaction mixture clean-up and 15 minute agarose gel purification protocols available
• Efficient removal of reaction contaminants - including enzymes, proteins, primers dimers, dNTPs, and salts
• Flexible—does not require precise gel slice quantification weighting
Applications
The purified DNA can be used in common downstream applications:
• Sequencing
• Restriction digestion
• PCR
• qPCR
• Labeling
• Ligation
• Cloning
• In vitro transcription
• Blotting
• In situ hybridization
Includes
• Binding Buffer
• Extraction Buffer
• Prewash Buffer (conc.)
• Wash Buffer (conc.)
• Elution Buffer
• DNA Purification Micro Column & Collection Tube
Specifications
Specifications
| Tipo di colonna | Spin Column |
| Formato | Spin Column |
| Isolation Technology | Silica Column |
| Tipo di campione | DNA, Gel Samples |
| Da utilizzare con (applicazione) | Real-Time Quantitative PCR (qPCR), Cloning, Southern Blotting, Nucleic Acid Labeling, Sequencing, PCR, In Vitro Transcription |
| Compatibilità ad alta produttività | Not High-throughput Compatible (Manual) |
| Linea di prodotti | GeneJET |
| Product Type | Gel Extraction and DNA Cleanup Kit |
| Quantità | 50 Preps |
| Bersaglio | DNA from Enzymatic Reactions (e.g. PCR) |
| Show More |
Safety and Handling
- GeneJET Gel Extraction and DNA Cleanup Micro Kit
- Attenzione
- Tossicità acuta Categoria 4
- Corrosione/irritazione della pelle Categoria 2
- Lesione oculare grave/irritazione oculare Categoria 2
- PERICOLO A LUNGO TERMINE PER L'AMBIENTE ACQUATICO Cronico 3
- H302-Nocivo se ingerito.
- H315-Provoca irritazione cutanea.
- H319-Provoca grave irritazione oculare.
- H412-Nocivo per gli organismi acquatici con effetti di lunga durata.
- EUH032-A contatto con acidi libera gas molto tossici.
- P280-Indossare guanti/indumenti protettivi/Proteggere gli occhi/il viso.
- P270-Non mangiare, né bere, né fumare durante l'uso.
- P273-Non disperdere nell'ambiente.
- P321-Trattamento specifico (vedere su questa etichetta).
- P362+P364-Togliere tutti gli indumenti contaminati e lavarli prima di indossarli nuovamente.
- P301+P312-IN CASO DI INGESTIONE accompagnata da malessere: contattare un CENTRO ANTIVELENI/medico
- P330-Sciacquare la bocca.
- P305+P351+P338-IN CASO DI CONTATTO CON GLI OCCHI: sciacquare accuratamente per parecchi minuti. Togliere le eventuali lenti a contatto se è agevole farlo. Continuare a sciacquare.
- P501-Smaltire il prodotto/recipiente in .
- MIXTURE LIST-Contain: guanidinium thiocyanate, guanidinium chloride
For Research Use Only. Not for use in diagnostic procedures.
By clicking Submit, you acknowledge that you may be contacted by Fisher Scientific in regards to the feedback you have provided in this form. We will not share your information for any other purposes. All contact information provided shall also be maintained in accordance with our Privacy Policy.