missing translation for 'onlineSavingsMsg'
Learn More

Applied Biosystems™ TaqMan™ MGB Probe

Código de producto. 13243744 Tienda Applied Biosystems Productos
Cambiar vista
Click to view available options
5'-Primer-Modifizierung:
ABY
Cyanine 5
FAM, NED, TET, VIC
JUN
Menge:
20,000 pmol
20,000 pmol Scale
50,000 pmol
50,000 pmol Scale
6,000 pmol
6.000 pmol-Skala
Tamaño de la unidad:
1 Stück
50000 Pikomol
12 product options available for selection
Product selection table with 12 available options. Use arrow keys to navigate and Enter or Space to select.
Código de producto. 5'-Primer-Modifizierung Menge Tamaño de la unidad
13243744 FAM, NED, TET, VIC 20,000 pmol Scale 1 Stück
30564901 ABY 6,000 pmol 1 Stück
30564944 ABY 20,000 pmol 1 Stück
30565004 ABY 50,000 pmol 1 Stück
30564902 JUN 6,000 pmol 1 Stück
30565020 JUN 20,000 pmol 1 Stück
30565217 JUN 50,000 pmol 1 Stück
30565243 Cyanine 5 6,000 pmol 1 Stück
30565016 Cyanine 5 20,000 pmol 1 Stück
30565238 Cyanine 5 50,000 pmol 1 Stück
12005030 FAM, NED, TET, VIC 6.000 pmol-Skala 1 Stück
15502423 FAM, NED, TET, VIC 50,000 pmol Scale 50000 Pikomol
Use arrow keys to navigate between rows. Press Enter or Space to select a product option. 12 options available.
12 options
Este artículo no se puede devolver. Vea la política de devoluciones
Código de producto. 13243744 Proveedor Applied Biosystems™ N.º de proveedor 4316033
Black Friday beginnt hier
Verwenden Sie den Aktionscode 27984
Ver todas las promociones
 Eingeschränkter Artikel
Verfügbar ab: 11-01-2027
Añadir a la cesta
Añadir a la cesta

missing translation for 'validMainframeMsg'

Este artículo no se puede devolver. Vea la política de devoluciones

Kundenspezifische TaqMan™ Probe

Custom TaqMan probes are dual-labeled primers suitable for use in any real-time PCR application. They incorporate a 5' reporter dye and a 3' nonfluorescent quencher/Minor Groove Binder (MGB). Choose from FAM, VIC, ABY, JUN, Cyanine 5, TET, and NED as reporters. Probes are HPLC-purified.

Applied Biosystems TaqMan MGB (minor groove binder) probes are dual-labeled probes used for real-time PCR applications using TaqMan chemistry. TaqMan MGB Probes incorporate a 5' fluorescent reporter dye and a 3' nonfluorescent quencher (NFQ). The NFQ offers the advantage of lower background signal, which results in better precision in quantitation. Custom TaqMan MGB probes are HPLC-purified and available with FAM, VIC, ABY, JUN, Cyanine 5, TET, and NED reporter dyes.

Shorter, more specific probes

TaqMan MGB probes include a MGB moiety at the 3' end that increases the melting temperature (Tm) of the probe and stabilizes probe/target hybrids. This means that TaqMan MGB probes can be significantly shorter than traditional probes, providing better sequence discrimination and flexibility to accommodate more targets.

Nonfluorescent quencher (NFQ) maximizes sensitivity

TaqMan MGB probes incorporate an NFQ to absorb (quench) signal from the fluorescent dye label at the other end of the probe. The properties of the NFQ combined with the short length of the MGB probe result in lower background signal than with non-MGB NFQ probes. Lower background means increased sensitivity and precision in your data.

Multiplexing

The availability of MGB probes for up to five channels allows for higher-order multiplexing, enabling detection of more targets from the same samples.

Guaranteed yield

The unit size you select is based on the minimum amount we will deliver, not on synthesis starting amount.

Approximate ship time

4–10 days in North America, 5-10 days in Europe

We also offer:

  • Applied Biosystems custom primers and other types of TaqMan probes.
  • TaqMan MGB probes and primers available as predesigned and pre-formulated TaqMan Assays.
  • Commercial manufacturing products and services, including OEM and GMP oligo manufacturing.

Need a different dye or concentration or a larger lot size? The TaqMan Custom Assay and Oligo Service offers custom products that you can tailor to meet your experimental needs.

TRUSTED_SUSTAINABILITY

Especificaciones

3'-Primer-Modifizierung MGB-NFQ
5'-Primer-Modifizierung FAM, NED, TET, VIC
Inhalt und Lagerung 1 Röhrchen mit einer doppelt markierten Sonde in Lösung.

Bei -15 bis -25 °C lagern
Form Flüssig
Format Tube
Zur Verwendung mit (Geräte) 7500 System, 7500 Fast System, 7900HT System, StepOne™, StepOnePlus™, ViiA™ 7 System, QuantStudio™ 3, QuantStudio™ 5, QuantStudio™ 6 Flex, QuantStudio™ 7 Flex, QuantStudio 6 Pro, QuantStudio 7 Pro, QuantStudio™ 12k Flex, QuantStudio™ Absolute Q Digital PCR System
Interne Sondenmodifikation Keine
Marker oder Farbstoff FAM, VIC, NED, TET
Produktlinie TaqMan
Produkttyp TaqMan Sonde
Reinigungsverfahren HPLC
Reinheits- oder Qualitätsgrad HPLC
Menge 20,000 pmol Scale
Versandbedingung Raumtemperatur
Zur Verwendung mit (Anwendung) Real-Time PCR (qPCR)
Mostrar más Mostrar menos

Nur für Forschungszwecke. Nicht zur Verwendung bei diagnostischen Verfahren.

Título del producto
Seleccione un problema

Al hacer clic en Enviar, acepta que Fisher Scientific se ponga en contacto con usted en relación con los comentarios que ha proporcionado en este formulario. No compartiremos su información para ningún otro fin. Toda la información de contacto proporcionada se mantendrá de acuerdo con nuestra Política de Privacidad. Política de privacidad.