missing translation for 'onlineSavingsMsg'
Learn More

Invitrogen™ Click-iT™ TUNEL Alexa Fluor Imaging Assays for Microscopy & HCS

Codice prodotto. 10338924
Cambia vista
Click to view available options
Colore:
Far-Red
Green
Red
Label or Dye:
Alexa Fluor 488, Hoechst 33342
Alexa Fluor 594, Hoechst 33342
Alexa Fluor 647, Hoechst 33342
Dimensione della confezione:
Pezzo
3 product options available for selection
Product selection table with 3 available options. Use arrow keys to navigate and Enter or Space to select.
Codice prodotto. Colore Label or Dye Dimensione della confezione
10338924 Far-Red Alexa Fluor 647, Hoechst 33342 Pezzo
10024014 Red Alexa Fluor 594, Hoechst 33342 Pezzo
10798585 Green Alexa Fluor 488, Hoechst 33342 Pezzo
Use arrow keys to navigate between rows. Press Enter or Space to select a product option. 3 options available.
3 options
Les retours ne sont pas autorisés pour ce produit. Consulta la politica di reso
Codice prodotto. 10338924 Fornitore Invitrogen™ N. del fornitore C10247
Black Friday Starts Here
Usa il codice promozionale 27984
Visualizza tutte le promozioni
 Articolo soggetto a restrizioni
Lager vorrätig
Aggiungi al carrello
Aggiungi al carrello

missing translation for 'validMainframeMsg'

Les retours ne sont pas autorisés pour ce produit. Consulta la politica di reso

Includes

One kit containing sufficient reagents to perform 1 x 96 tests or 50 coverslips.

Screen apoptotic cells with Click-iT TUNEL Assay kits, which offer easy Alexa Fluor dye incorporation and can be multiplexed with GFP and RFP.

Screen apoptotic cells easily and efficiently in just two hours with the Click-iT TUNEL Alexa Fluor 488, 594, and 647 imaging assays. Intended for use with microscopy and high-content screening (HCS), these TUNEL assay kits use a copper-catalyzed reaction to detect incorporated alkyne-modified dUTPs on terminal DNA ends of fragmented DNA. Compared with assays using other modified nucleotides, these apoptosis detection kits are fast (complete within two hours) and can detect a higher percentage of apoptotic cells under identical conditions. Click-iT TUNEL assays also allow multiplexing with surface and intracellular biomarker detection methods, including those that measure fluorescent signal from GFP or RFP.

Apoptosis is marked by defined cellular processes, including cell rounding, blebbing, and DNA fragmentation. The TUNEL assay is the most widely used analytical method to detect fragmented DNA in apoptotic cells in tissue samples, beginning with the incorporation of modified dUTPs at the 3’-OH ends of fragmented DNA. The dUTPs often include a fluorophore molecule. Due to the size of the fluorophore, modified dUTPs can display lower than expected incorporation rates, negatively affecting the sensitivity of the TUNEL assay. Quite often, fluorophores used in currently available TUNEL assay kits exhibit photobleaching and fluorescent spectral overlap issues, both of which reduce the sensitivity of and ability to multiplex these assays.

The Click-iT Plus TUNEL assay was developed to address these issues and is based on a copper (I) catalyzed (i.e., click) reaction between an azide and alkyne. The small size of the Alexa Fluor azide, which has a molecular weight of about 1 kDa, enables easier incorporation of the Alexa Fluor 488, 594, or 647 dye into complex samples, as compared to larger (MW ˜100,000 Da) antibodies. This permits mild fixation or permeabilization and faster assay turnaround time (about two hours) and enables the detection of a higher percentage of apoptotic cells under identical conditions. Because of its gentle reaction conditions, the Click-iT Plus TUNEL assay can also be multiplexed with fluorescent proteins or dyes.

The Click-iT TUNEL Alexa Fluor imaging assays contain all components needed to accurately and reliably detect apoptosis in adherent cells grown on coverslips or 96-well microplates, and they also include DNase I to generate strand breaks for the positive control.

Order Info

Shipping Condition: Dry ice

TRUSTED_SUSTAINABILITY

Specifica

Descrizione Click-iT TUNEL Alexa Fluor™ 647 Imaging Assay
Quantità 1 kit
Formato 96-well Plate
Product Type Imaging Assay
Content And Storage Store at ≤-20°C and protected from light.
Excitation/Emission 650/665
N. di reazioni 1 X 96 tests or 50 coverslips
Colore Far-Red
Shipping Condition Dry Ice
Linea di prodotti Click-iT
Metodo di rilevamento Fluorescence
Da utilizzare con (apparecchiatura) Fluorescence Microscope, High Content Instrument
Label or Dye Alexa Fluor 647, Hoechst 33342
Tipo di etichetta Alexa Fluor™ Dyes, Classic Dyes
Vedi altri risultati Mostra meno risultati
Titolo del prodotto
Selezionare un problema

Facendo clic su Invia, l'utente riconosce che potrebbe essere contattato da Fisher Scientific in merito al feedback fornito in questo modulo. Non condivideremo le vostre informazioni per altri scopi. Tutte le informazioni di contatto fornite saranno conservate in conformità con la nostra Politica sulla privacy. Informativa sulla privacy.