missing translation for 'onlineSavingsMsg'
Learn More

Invitrogen™ Click-iT™ EdU Alexa Fluor™ 647 Flow Cytometry Assay Kit

Codice prodotto. 12043795
Cambia vista
Click to view available options
Quantità:
100 assays
50 assays
Dimensione della confezione:
50 reazioni
Pezzo
2 product options available for selection
Product selection table with 2 available options. Use arrow keys to navigate and Enter or Space to select.
Codice prodotto. Quantità Dimensione della confezione
12043795 50 assays 50 reazioni
11370952 100 assays Pezzo
Use arrow keys to navigate between rows. Press Enter or Space to select a product option. 2 options available.
2 options
Les retours ne sont pas autorisés pour ce produit. Consulta la politica di reso
Codice prodotto. 12043795 Fornitore Invitrogen™ N. del fornitore C10424
Spotlight Offers
Usa il codice promozionale 28038
Visualizza tutte le promozioni
 Articolo soggetto a restrizioni
Lager vorrätig
Aggiungi al carrello
Aggiungi al carrello

missing translation for 'validMainframeMsg'

Les retours ne sont pas autorisés pour ce produit. Consulta la politica di reso

Click-iT™ EdU Alexa Fluor™ 647 Flow Cytometry Assay Kit

The Click-iT™ EdU Alexa Fluor™ 647 Flow Cytometry Assay Kit provides a simplified, more robust assay for analyzing DNA replication in proliferating cells as compared to traditional BrdU methods. Newly synthesized DNA is analyzed using the 633/5 nm laser of the flow cytometer.

  • Accurate--Superior Results compared to BrdU Assays
  • Fast--Results in as little as 90 minutes
  • Economical--More assays per kit

    View selection guide for all Click-iT™ EdU and Click-iT™ Plus EdU assays for flow cytometry.

    An Advanced Method Giving You Results Superior to BrdU
    The most accurate method of proliferation analysis is direct measurement of DNA synthesis. Originally, this was performed through incorporation of radioactive nucleosides, i.e., 3H-thymidine. This method was replaced by antibody-based detection of the nucleoside analog bromodeoxyuridine (BrdU). The Click-iT™ EdU Flow Cytometry Assay Kits are novel alternatives to the BrdU assay. EdU (5-ethynyl-2´-deoxyuridine) is a thymidine analog which is incorporated into DNA during active DNA synthesis. Detection is based on click chemistry: a copper catalyzed covalent reaction between an azide and an alkyne. In this application, the alkyne is found in the ethynyl moiety of EdU, while the azide is coupled to Alexa Fluor ™ 488, Alexa Fluor™ 647, or Pacific BlueTM dyes. Standard flow cytometry methods are used for determining the percentage of S-phase cells in the population (Fig 1).

    Mild Conditions Allow Use with Cell Cycle Dyes and Antibodies
    The advantages of Click-iT™ EdU labeling are readily evident while performing the assay (Fig 2). The small size of the dye azide allows for efficient detection of the incorporated EdU using mild conditions, while standard aldehyde-based fixation and detergent permeabilization are sufficient for the Click-iT™ detection reagent to gain access to the DNA. This is in contrast to BrdU assays that require DNA denaturation (using HCl, heat, or digestion with DNase) to expose the BrdU so that it may be detected with an anti-BrdU antibody. Sample processing for the BrdU assay can result in signal alteration of the cell cycle distribution as well as destruction of antigen recognition sites when using the HCl method. In contrast, the easy-to-use EdU cell proliferation kit is compatible with cell cycle dyes. This EdU assay kit can also be multiplexed with antibodies against surface and intracellular markers.

    Quick and Simple Protocol
    The Click-iT™ EdU protocol is based on the aldehyde fixation and detergent permeabilization steps for immunohistochemical antibody labeling, but EdU is compatible with other
    fixation/permeabilization agents including saponin and methanol. In just five steps you’ll be ready to analyze your cell proliferation data:

  • Treat cells with EdUM
  • Fix and permeabilize cells
  • Detect S-phase cells with Click-iT™ detection cocktail for 30 min
  • Wash once
  • Analyze

    Get Accurate Results Economically
    By increasing the number of assays per kit, the Click-IT™ EdU Alexa Fluor™ 647 Flow Cytometry Assay Kit is less expensive than the traditional BrdU assays making them ideal for large experiments.

    For research use only. Not intended for any human or animal therapeutic of diagnostic use.
  • TRUSTED_SUSTAINABILITY

    Specifica

    Content And Storage Contains EdU (5-ethynyl-2' -deoxyuridine), Alexa Fluor™ 647 azide, anhydrous dimethylsulfoxide (DMSO), Click-iT™ fixative, Click-iT™ saponin-based permeabilization and wash buffer, copper (II) sulfate,, and Click-iT™ EdU buffer additive.
  • Store at 2°C to 8°C
  • Dessicate and protect from light.
    Metodo di rilevamento Fluorescence
    Da utilizzare con (apparecchiatura) Flow Cytometer
    Product Type Flow Cytometry Assay Kit
    Tipo di colorante Alexa Fluor™ 647
    Formato Tube(s)
    Product Line Click-iT
    Quantità 50 assays
    Shipping Condition Room Temperature
    Emissione lunghezza d'onda 650/670
    compliance-icons compliance-icons compliance-icons
    Identificativo prodotto
    • 647 Flow Cytometry Assay Kit
    Avvertenza
    • Pericolo
    Categoria di pericolo
    • PERICOLO A LUNGO TERMINE PER L'AMBIENTE ACQUATICO Cronico 3
    • Cancerogenicità Categoria 1
    • Lesione oculare grave/irritazione oculare Categoria 1
    • Mutagenicità di cellule germinali Categoria 2
    • Sensibilizzazione della pelle Categoria 1
    • Tossicità specifica per organi bersaglio (esposizione singola) Categoria 2
    Indicazioni di pericolo
    • H317-Può provocare una reazione allergica cutanea.
    • H318-Provoca gravi lesioni oculari.
    • H341-Sospettato di provocare alterazioni genetiche.
    • H350-Può provocare il cancro.
    • H371-Può provocare danni agli organi.
    • H412-Nocivo per gli organismi acquatici con effetti di lunga durata.
    Consigli di prudenza
    • P201-Procurarsi istruzioni specifiche prima dell'uso.
    • P261-Evitare di respirare la polvere/i fumi/i gas/la nebbia/i vapori/gli aerosol.
    • P264-Lavare accuratamente dopo l'uso.
    • P270-Non mangiare, né bere, né fumare durante l'uso.
    • P280-Indossare guanti/indumenti protettivi/Proteggere gli occhi/il viso.
    • P302+P352-IN CASO DI CONTATTO CON LA PELLE: lavare abbondantemente con acqua/.
    • P305+P351+P338-IN CASO DI CONTATTO CON GLI OCCHI: sciacquare accuratamente per parecchi minuti. Togliere le eventuali lenti a contatto se è agevole farlo. Continuare a sciacquare.
    • P308+P313-IN CASO di esposizione o di possibile esposizione, consultare un medico.
    • P310-Contattare immediatamente un CENTRO ANTIVELENI/un medico .
    • P332+P313-In caso di irritazione della pelle: consultare un medico.
    • P501b-Smaltire il prodotto/recipiente in conformità con le disposizioni locali/regionali/nazionali/internazionali.
    Informazioni supplementari
    • MIXTURE LIST-Contain: Paraformaldehyde

    For Research Use Only. Not for use in diagnostic procedures.

    Titolo del prodotto
    Selezionare un problema

    Facendo clic su Invia, l'utente riconosce che potrebbe essere contattato da Fisher Scientific in merito al feedback fornito in questo modulo. Non condivideremo le vostre informazioni per altri scopi. Tutte le informazioni di contatto fornite saranno conservate in conformità con la nostra Politica sulla privacy. Informativa sulla privacy.