missing translation for 'onlineSavingsMsg'
Learn More

Applied Biosystems™ CLA IdentiFiler™ Plus PCR Amplification Kit

Codice prodotto. 31722952 Sfoglia Tutto Applied Biosystems Prodotti
Cambia vista
Click to view available options
Quantità:
200 x 25 μL Reactions
Dimensione della confezione:
200 reazioni
1 product options available for selection
Product selection table with 1 available options. Use arrow keys to navigate and Enter or Space to select.
Codice prodotto. Quantità Dimensione della confezione
31722952 200 x 25 μL Reactions 200 reazioni
Use arrow keys to navigate between rows. Press Enter or Space to select a product option. 1 options available.
1 options
Les retours ne sont pas autorisés pour ce produit. Consulta la politica di reso
Codice prodotto. 31722952 Fornitore Applied Biosystems™ N. del fornitore A65672
 Articolo soggetto a restrizioni
Lager vorrätig
Aggiungi al carrello
Aggiungi al carrello

missing translation for 'validMainframeMsg'

Les retours ne sont pas autorisés pour ce produit. Consulta la politica di reso

The CLA (Cell Line Authentication) IdentiFiler Plus PCR Amplification Kit simplifies the amplification step during authentication of cell lines.

The CLA (Cell Line Authentication) IdentiFiler Plus PCR Amplification Kit simplifies the amplification step during authentication of cell lines. It includes the same primers and allelic ladder as the widely used AmpFLSTR Identifiler Plus kit and harnesses next-generation PCR amplification technology to help provide enhanced sensitivity, a cleaner baseline, improved performance with mixtures, and the ability to overcome high levels of PCR inhibition. The kit includes GeneScan 600 LIZ Size Standard v2.0, a five-dye-labeled, high-density size standard for the reproducible sizing of fragment analysis data.

Features of the CLA IdentiFiler Plus PCR Amplification Kit include:

  • 5-dye, 16-locus STR kit compatible with all cell line databasing loci standards
  • Improved version of legacy AmpFLSTR Identifiler Plus kit
  • Size standard included for ease of purchase
  • Compatible with SeqStudio, 3730/xL, and 3500/xL genetic analyzers

Cell line authentication using short tandem repeat (STR) analysis kits can be used both for human sample authentication (HSA) and mixed sample analysis (MSA). In HSA, there is a need to verify the DNA profile of the sample to check for sample cross-contamination or sample mix-up, or to perform a quality check. For MSA there is a need to deconvolute the presence of multiple contributors in a sample (chimerism) through identification of multiple DNA genotypes in the sample.

TRUSTED_SUSTAINABILITY

Specifica

Content And Storage • AmpFLSTR Identifiller Plus PCR Ampl Kit
• GS Liz600 Size Standard
Metodo di rilevamento Gel Electrophoresis
Forma Liquid
Formato Kit
GC-Rich PCR Performance High
PCR Method End-point PCR
Polimerasi AmpliTaq Gold DNA Polymerase
Reaction Speed 60 min.
Tecnica STR (Short Tandem Repeats) Analysis
Da utilizzare con (apparecchiatura) SeqStudio Flex 3500, SeqStudio 3730xl Genetic Analyzers
Tipo di kit Multicomponent
Label or Dye LIZ, FAM, NED, PET, VIC
Quantità 200 x 25 μL Reactions
Specie Human
Target Organism Class Human cell lines
Da utilizzare con (applicazione) Genotyping, Cell Analysis
Purification Target Cell DNA
Reaction Format Tube
Tipo di campione Genomic DNA
Starting Material Cell Line Culture
Vedi altri risultati Mostra meno risultati

For Research Use Only. Not for use in diagnostic procedures.

Titolo del prodotto
Selezionare un problema

Facendo clic su Invia, l'utente riconosce che potrebbe essere contattato da Fisher Scientific in merito al feedback fornito in questo modulo. Non condivideremo le vostre informazioni per altri scopi. Tutte le informazioni di contatto fornite saranno conservate in conformità con la nostra Politica sulla privacy. Informativa sulla privacy.