missing translation for 'onlineSavingsMsg'
Learn More

Invitrogen™ Annexin V Ready Flow Conjugates for Apoptosis Detection

Codice prodotto. 15884943
Cambia vista
Click to view available options
Excitation/Emission:
410/455
495/519
650/660
650/665
Colore:
Blue
Far-Red
Green
Red
Coniugato:
APC (Allophycocyanin)
Alexa Fluor 488
Alexa Fluor 647
Pacific Blue
Dimensione della confezione:
120 reazioni
4 product options available for selection
Product selection table with 4 available options. Use arrow keys to navigate and Enter or Space to select.
Codice prodotto. Excitation/Emission Colore Coniugato Dimensione della confezione
15884943 650/660 Red APC (Allophycocyanin) 120 reazioni
15719039 495/519 Green Alexa Fluor 488 120 reazioni
15874943 650/665 Far-Red Alexa Fluor 647 120 reazioni
15894943 410/455 Blue Pacific Blue 120 reazioni
Use arrow keys to navigate between rows. Press Enter or Space to select a product option. 4 options available.
4 options
Les retours ne sont pas autorisés pour ce produit. Consulta la politica di reso
Codice prodotto. 15884943 Fornitore Invitrogen™ N. del fornitore R37176
Follow the Workflow - Explore the Savings
Usa il codice promozionale 27967
Visualizza tutte le promozioni
 Articolo soggetto a restrizioni
Verfügbar ab: 03-12-2026
Aggiungi al carrello
Aggiungi al carrello

missing translation for 'validMainframeMsg'

Les retours ne sont pas autorisés pour ce produit. Consulta la politica di reso

Annexin V conjugate stains enable you to easily determine apoptotic cells via flow cytometry.

Enjoy the convenience of ready-to-use Annexin V Ready Flow stand-alone conjugate stains, which offer up to 100-fold fluorescence signal intensity between apoptotic and non-apoptotic cells using flow cytometry. There is no need to dilute, weigh, or pipette the conjugate stains; simply add one drop into cells, incubate, and analyze.

Annexin V conjugates provide quick and reliable detection methods for studying the externalization of phosphatidylserine, an indicator of intermediate stages of apoptosis. The difference in fluorescence intensity between apoptotic and nonapoptotic cells stained with our fluorescent annexin V conjugates, as measured by flow cytometry, is typically about 100-fold.

The Annexin V Ready Flow conjugates are provided as ready-to-use, direct-to-sample apoptotic cell stains. Simply add one drop from the dropper bottle directly into 1 x 105 cells in 2.5 mM Ca2+-containing cell culture medium or annexin binding buffer (Cat. Nos. V13246 or BMS500BB), incubate, and analyze. The traditional annexin staining protocol can be used as an alternative method by replacing the addition of 5 μL annexin conjugate with the addition of 1 drop from the Ready Flow dropper bottle, following the volumes and incubation conditions as indicated.

The Annexin V Alexa Fluor 488 conjugate is excitable at 495 nm with an emission peak at 519 nm.

The Annexin V Alexa Fluor 647 conjugate is excitable at 650 nm with an emission peak at 665 nm.

The Annexin V APC conjugate is excitable at 650 nm with an emission peak at 660 nm.

The Annexin V Pacific Blue conjugate is excitable at 410 nm with an emission peak at 455 nm.

Annexin V staining to detect apoptotic cells can only be done on live cells and tissue. If samples are to be fixed post-staining, there are specific conditions required to achieve transient retention of signal. These include use of an alcohol-free, aldehyde-based fixation method, use of buffers containing Ca2+ and avoidance of surfactants/detergents. For your convenience, we also offer a concentrated annexin-binding buffer that facilitates the binding of annexin V to phosphatidylserine in apoptosis assays.

TRUSTED_SUSTAINABILITY

Specifica

Descrizione Annexin V APC Ready Flow Conjugate
Quantità 2 Dropper Bottles
Product Type Ready Flow Conjugate
Content And Storage Store at 2-8°C.
Flow Cytometer Laser Lines Red
Excitation/Emission 650/660
N. di reazioni 120
Colore Red
Shipping Condition Room Temperature
Coniugato APC (Allophycocyanin)
Da utilizzare con (apparecchiatura) Flow Cytometer
Vedi altri risultati Mostra meno risultati
Titolo del prodotto
Selezionare un problema

Facendo clic su Invia, l'utente riconosce che potrebbe essere contattato da Fisher Scientific in merito al feedback fornito in questo modulo. Non condivideremo le vostre informazioni per altri scopi. Tutte le informazioni di contatto fornite saranno conservate in conformità con la nostra Politica sulla privacy. Informativa sulla privacy.