missing translation for 'onlineSavingsMsg'
Learn More

Invitrogen™ Annexin V Ready Flow Conjugates for Apoptosis Detection

Artikelnummer. 15884943
Ansicht ändern
Click to view available options
Anregung/Emission:
410/455
495/519
650/660
650/665
Farbe:
Blau
Grün
Rot
Tiefrot
Konjugat:
APC (Allophycocyanin)
Alexa Fluor 488
Alexa Fluor 647
Pacific Blue
Packungsgröße:
120 Reaktionen
4 product options available for selection
Product selection table with 4 available options. Use arrow keys to navigate and Enter or Space to select.
Artikelnummer. Anregung/Emission Farbe Konjugat Packungsgröße
15884943 650/660 Rot APC (Allophycocyanin) 120 Reaktionen
15719039 495/519 Grün Alexa Fluor 488 120 Reaktionen
15874943 650/665 Tiefrot Alexa Fluor 647 120 Reaktionen
15894943 410/455 Blau Pacific Blue 120 Reaktionen
Use arrow keys to navigate between rows. Press Enter or Space to select a product option. 4 options available.
4 options
Dieser Artikel kann nicht zurückgegeben werden. Rückgaberichtlinie anzeigen
Artikelnummer. 15884943 Lieferant Invitrogen™ Lieferanten-Nr. R37176
Folgen Sie dem Workflow - Entdecken Sie die Einsparungen
Verwenden Sie den Aktionscode 27967
Alle Werbeaktionen anzeigen
 Eingeschränkter Artikel
Verfügbar ab: 02-12-2026
Zum Warenkorb hinzufügen
Zum Warenkorb hinzufügen

missing translation for 'validMainframeMsg'

Dieser Artikel kann nicht zurückgegeben werden. Rückgaberichtlinie anzeigen

Annexin V Konjugat-Färbemittel ermöglichen die einfache Bestimmung apoptotischer Zellen über die Durchflusszytometrie.

Die gebrauchsfertigen eigenständigen Annexin V Ready Flow Konjugat-Färbemittel bieten mittels Durchflusszytometrie eine bis zu 100-fache Signalintensität bei der Fluoreszenz zwischen apoptotischen und nicht apoptotischen Zellen. Es ist nicht erforderlich, die Konjugat-Färbemittel zu verdünnen, zu wiegen oder zu pipettieren. Fügen Sie einfach einen Tropfen in die Zellen ein, inkubieren und analysieren Sie sie.

Annexin V conjugates provide quick and reliable detection methods for studying the externalization of phosphatidylserine, an indicator of intermediate stages of apoptosis. The difference in fluorescence intensity between apoptotic and nonapoptotic cells stained with our fluorescent annexin V conjugates, as measured by flow cytometry, is typically about 100-fold.

The Annexin V Ready Flow conjugates are provided as ready-to-use, direct-to-sample apoptotic cell stains. Simply add one drop from the dropper bottle directly into 1 x 105 cells in 2.5 mM Ca2+-containing cell culture medium or annexin binding buffer (Cat. Nos. V13246 or BMS500BB), incubate, and analyze. The traditional annexin staining protocol can be used as an alternative method by replacing the addition of 5 μL annexin conjugate with the addition of 1 drop from the Ready Flow dropper bottle, following the volumes and incubation conditions as indicated.

The Annexin V Alexa Fluor 488 conjugate is excitable at 495 nm with an emission peak at 519 nm.

The Annexin V Alexa Fluor 647 conjugate is excitable at 650 nm with an emission peak at 665 nm.

The Annexin V APC conjugate is excitable at 650 nm with an emission peak at 660 nm.

The Annexin V Pacific Blue conjugate is excitable at 410 nm with an emission peak at 455 nm.

Annexin V staining to detect apoptotic cells can only be done on live cells and tissue. If samples are to be fixed post-staining, there are specific conditions required to achieve transient retention of signal. These include use of an alcohol-free, aldehyde-based fixation method, use of buffers containing Ca2+ and avoidance of surfactants/detergents. For your convenience, we also offer a concentrated annexin-binding buffer that facilitates the binding of annexin V to phosphatidylserine in apoptosis assays.

TRUSTED_SUSTAINABILITY

Spezifikation

Beschreibung Annexin V APC Ready Flow Konjugat
Menge 2 Dropper Bottles
Produkttyp Ready Flow Konjugat
Inhalt und Lagerung Bei 2-8°C lagern.
Durchflusszytometer-Laserlinien Rot
Anregung/Emission 650/660
Anzahl Reaktionen 120
Farbe Rot
Versandbedingung Raumtemperatur
Konjugat APC (Allophycocyanin)
Zur Verwendung mit (Geräte) Durchflusszytometer
Mehr anzeigen Weniger anzeigen
Name des Produkts
Wählen Sie ein Thema

Indem Sie auf Absenden klicken, erklären Sie sich damit einverstanden, dass Fisher Scientific sich mit Ihnen in Verbindung setzen kann, um Ihr Feedback in diesem Formular zu bearbeiten. Wir werden Ihre Informationen nicht für andere Zwecke weitergeben. Alle bereitgestellten Kontaktinformationen werden in Übereinstimmung mit unserer Datenschutzrichtlinie aufbewahrt. Datenschutzrichtlinie.