Learn More
Invitrogen™ Tempus™ Spin RNA Isolation Kit
Descrizione
Includes
RNA purification filters, 2mL collection tubes, 1X PBS, RNA Purification Resuspension Solution, RNA Purification Wash Solution 1, RNA Purification Wash Solution 2, and Nucleic Acid Purification Elution Solution
This Applied Biosystems product is for the fast, easy, glass fiber filter-based isolation of RNA from blood using standard laboratory equipment in about one hour. Contains sufficient reagents for RNA purification from 50 samples. Gene expression profiling and analysis of whole blood is becoming an increasingly important life science tool. Accurately measuring the molecular profile of blood-based RNA transcripts is a critical need in areas of research such as disease association studies, biomarker discovery and validation, and monitoring of drug treatment regimes.
- Isolate high-quality RNA from blood, suitable for real-time PCR and microarray analysis
- Obtain highly stable RNA virtually free of RNase activity, contaminating gDNA, or RT-PCR inhibitors
- Easy workflow requires only standard laboratory centrifuges and ∼1 hour of time
- No separate RBC lysis or proteinase K treatment required
Performance with Ease
The ability of the Tempus system (Tempus Blood RNA Tubes and Tempus Spin RNA Isolation Kit) to stabilize RNA expression profiles has been tested over a range of storage conditions. The combination provides stable RNA, high yields of purified RNA (observed yields of 6 to 25μg from a full blood draw from normal, healthy donors), and high-quality RNA (A260/280 ratio greater than 1.9 and RIN greater than 7.0) suitable for use in downstream applications such as quantitative PCR, microarray profiling, and other RNA analysis methods.
Accessory Product
The highly unstable nature of RNA transcripts ex vivo creates an even greater challenge for accurate expression analysis. Ongoing metabolic changes can drastically affect gene expression profiles in as little as one hour in standard blood collection tubes. Use of the Applied Biosystems Tempus™ Blood RNA Tubes (Cat. No. 4342792) is therefore recommended. These tubes are designed for direct collection of 3mL of blood into a plastic, evacuated blood collection tube containing RNA Stabilizing Reagent. The RNA, and therefore the expression profile, is stable in the collection tube for up to five days at room temperature and a minimum of 7 days at 4°C
Not high-throughput compatible (Manual)
Specifica
Specifica
| Content And Storage | • 50 RNA Purification Filters; room temperature • 2 x 100 Collection Tubes; room temperature • 2 x 80 mL 1X PBS; room temperature • 24 mL RNA Purification Resuspension Solution; room temperature • 2 x 22 mL RNA Purification Wash Solution 1; room temperature • 120 mL RNA Purification Wash Solution 2; room temperature • 4 x 1.9 mL Nucleic Acid Purification Elution Solution; room temperature |
| Isolation Technology | Silica Spin Column |
| Purification Time | 40 min. |
| Volume di eluizione | 100 μL |
| Tipo di campione | Whole Blood |
| Tipo di prodotto finale | Total RNA |
| Compatibilità ad alta produttività | Not High-throughput Compatible (Manual) |
| Da utilizzare con (applicazione) | RT-PCR, qPCR, cDNA library construction, NGS, microarray analysis, blot hybridization, Northern blotting, in vitro translation, nuclease protection assays, nucleic acid labeling |
| Quantità | 50 Preps |
| Shipping Condition | Room Temperature |
| Vedi altri risultati |
Sicurezza e movimentazione
- Tempus Spin RNA Isolation Kit
- Pericolo
- Lesione oculare grave/irritazione oculare Categoria 2
- Liquido infiammabile Categoria 2
- Corrosione/irritazione della pelle Categoria 2
- H225-Liquido e vapori facilmente infiammabili.
- H315-Provoca irritazione cutanea.
- H319-Provoca grave irritazione oculare.
- P210-Tenere lontano da fonti di calore, superfici riscaldate, scintille, fiamme e altre fonti di innesco. Vietato fumare.
- P233-Tenere il recipiente ben chiuso.
- P242-Utilizzare solo utensili antiscintillamento.
- P243-Prendere precauzioni contro le scariche elettrostatiche.
- P264-Lavare accuratamente dopo l'uso.
- P280-Indossare guanti/indumenti protettivi/Proteggere gli occhi/il viso.
- P302+P352-IN CASO DI CONTATTO CON LA PELLE: lavare abbondantemente con acqua/.
- P303+P361+P353-IN CASO DI CONTATTO CON LA PELLE (o con i capelli): togliere immediatamente tutti gli indumenti contaminati. Sciacquare la pelle/fare una doccia.
- P305+P351+P338-IN CASO DI CONTATTO CON GLI OCCHI: sciacquare accuratamente per parecchi minuti. Togliere le eventuali lenti a contatto se è agevole farlo. Continuare a sciacquare.
- P332+P313-In caso di irritazione della pelle: consultare un medico.
- P337+P313-Se l'irritazione degli occhi persiste, consultare un medico.
- P362+P364-Togliere tutti gli indumenti contaminati e lavarli prima di indossarli nuovamente.
- P370+P378-In caso d'incendio: utilizzare per estinguere.
- P403+P235-Conservare in luogo fresco e ben ventilato.
- P501b-Smaltire il prodotto/recipiente in conformità con le disposizioni locali/regionali/nazionali/internazionali.
- MIXTURE LIST-Contain: ethanol, Guanidine hydrochloride
For Research Use Only. Not for use in diagnostic procedures.
Facendo clic su Invia, l'utente riconosce che potrebbe essere contattato da Fisher Scientific in merito al feedback fornito in questo modulo. Non condivideremo le vostre informazioni per altri scopi. Tutte le informazioni di contatto fornite saranno conservate in conformità con la nostra Politica sulla privacy. Informativa sulla privacy.