Invitrogen™ MEGAclear™ Transcription Clean-Up Kit
Description
The MEGAclear Transcription Clean-up Kit is designed for rapid high-throughput purification of RNA from enzymatic reactions such as in vitro transcription. The kit efficiently separates RNA from unincorporated NTPs, enzymes, and buffer components. The process is simple and fast, taking less than 30 minutes, and it recovers from 1 ng to 500 μg of RNA efficiently. The MEGAclear kit is appropriate for purification of ssRNA larger than 100 nt and dsRNA larger than 200 bp.
The MEGAclear kit purifies transcription reactions to produce high-quality RNA, free of unincorporated NTPs, enzymes, and buffer components, ideal for any downstream application that requires purified RNA. It can be used to remove nucleotides, short oligonucleotides,proteins, and salts from RNA. The RNA recovered can be used for any application that requires high purity RNA.
Use the MEGAclear lit to clean up any of the following:
- In vitro transcribed RNA:
- RNA from MEGAscript reactions
- Amino allyl-modified RNA
- Biotinyled RNA
- Cy dye labeled RNA
- Capped RNA (e.g., from mMESSAGE mMACHINE kit reactions)
- Total RNA
Using the MEGAclear kit
The protocol is quick and easy. The transcription reaction is mixed with Binding Solution, passed over an RNA-binding filter, and washed; an elution step releases the purified RNA, which is now ready for any application requiring highly pure synthetic or in vitro transcribed RNA. For RNA recovery of 70% or greater, single-stranded RNA should be >100 nt and double-stranded RNA should be >200 bp.
Specifications
Specifications
| Content And Storage | Binding Solution, Wash Solution Concentrate, and 5 M Ammonium Acetate are stored at 4°C. Elution Solution can be stored at any temperature, and Filter Cartridges and Collection and Elution Tubes are stored at room temperature. |
| Final Product Type | Purified Synthetic mRNA, Purified mRNA |
| Formato | Tube |
| Isolation Technology | Silica Spin Column |
| Purification Target | mRNA, Synthetic mRNA |
| Tipo di campione | mRNA, Synthetic mRNA |
| Da utilizzare con (applicazione) | In Vitro Transcription, synthetic mRNA, mRNA, transfection, LNPs, GENEart, linearized DNA plasmid, delivery, PCR products |
| Da utilizzare con (apparecchiatura) | Vacuum Manifold, Centrifuge |
| Compatibilità ad alta produttività | Not High-throughput Compatible (Manual) |
| N. di reazioni | 20 Preps |
| Show More |
Safety and Handling
- MEGAclear Transcription Clean-Up Kit
- Pericolo
- Tossicità acuta Categoria 4
- PERICOLO A LUNGO TERMINE PER L'AMBIENTE ACQUATICO Cronico 3
- Corrosione/irritazione della pelle Categoria 1C
- H302-Nocivo se ingerito.
- H314-Provoca gravi ustioni cutanee e gravi lesioni oculari.
- H412-Nocivo per gli organismi acquatici con effetti di lunga durata.
- P264-Lavare accuratamente dopo l'uso.
- P270-Non mangiare, né bere, né fumare durante l'uso.
- P273-Non disperdere nell'ambiente.
- P280-Indossare guanti/indumenti protettivi/Proteggere gli occhi/il viso.
- P301+P310-IN CASO DI INGESTIONE: contattare immediatamente un CENTRO ANTIVELENI/un medico
- P303+P361+P353-IN CASO DI CONTATTO CON LA PELLE (o con i capelli): togliere immediatamente tutti gli indumenti contaminati. Sciacquare la pelle/fare una doccia.
- P305+P351+P338-IN CASO DI CONTATTO CON GLI OCCHI: sciacquare accuratamente per parecchi minuti. Togliere le eventuali lenti a contatto se è agevole farlo. Continuare a sciacquare.
- P330-Sciacquare la bocca.
- P501b-Smaltire il prodotto/recipiente in conformità con le disposizioni locali/regionali/nazionali/internazionali.
- MIXTURE LIST-Contain: 2-Mercaptoethanol
For Research Use Only. Not for use in diagnostic procedures.