Learn More
Invitrogen™ MagMAX™-96 Total RNA Isolation Kit
Descrizione
Includes
Kit contents: 1 Processing Plate and Lid; 11mL Lysis/Binding Solution Concentrate; 18mL Wash Solution 1 Concentrate; 55mL Wash Solution 2 Concentrate; 12mL RNA Rebinding Concentrate; 10mL Elution Buffer; 6mL MagMAX TURBO DNase Buffer; 1.1mL RNA Binding Beads; 1.1mL Lysis/Binding Enhancer; 110μL TURBO DNase. Contains enough reagents to isolate RNA from 96 samples.
The MagMAX-96 Total RNA Isolation Kit is designed for the rapid, moderate-throughput purification of RNA from animal and plant cells and tissue. RNA purified using the kit is ideal for PCR and RT-PCR applications. The kit uses magnetic bead–based purification and includes sufficient reagents for 96 reactions.
Benefits of MagMAX magnetic bead–based purification
Magnetic beads offer many benefits compared to other technologies for isolating RNA. Beads bind RNA more efficiently than glass fiber filters, resulting in higher and more consistent RNA yields. Additionally, because filters are not used, there is no risk of filter clogging due to cellular particulates in samples. Since only a small volume of magnetic beads is needed for high-efficiency binding, the bound RNA can be eluted in just 20–50 μL of nuclease-free water, concentrating RNA from large, dilute samples.
Accommodates diverse sample types
The kit accommodates diverse biological samples and a broad range of cell and tissue input amounts. The kit is optimized for high-throughput isolation of RNA from 25 cells to 2 x 106 cells, as well as small plant and mammalian tissue samples (up to 10mg). The protocol is fully amenable to automation. Detailed guidelines for general automation are included with the kit.
- Enhanced lysis/binding conditions to accommodate larger sample inputs
- Reagents for TURBO DNase™ treatment included to minimize DNA contamination and preserve RNA integrity
- Includes protocol for RNA isolation from plant tissues
- 96 reactions per kit suitable for moderate throughput
- Automated protocols, high-throughput compatible users
Accessory products
Lysis/Binding Solution Concentrate, Wash Solution 1 Concentrate, and Wash Solution 2 Concentrate are components of the kit that may also be purchased separately. The Plant RNA Isolation Aid can be used in conjunction with the MagMAX-96 Total RNA Isolation Kit for the isolation of RNA from plant tissues.
Specifica
Specifica
| Content And Storage | • 1 Processing Plate; room temperature • 11 mL Lysis/Binding Solution (concentrated); room temperature • 18 mL Wash Solution 1 (concentrated); room temperature • 55 mL Wash Solution 2 (concentrated); room temperature • 12 mL RNA Rebinding (concentrated); room temperature • 10 mL Elution Buffer; room temperature • 6 mL MagMAX TURBO DNase Buffer; room temperature • 1.1 mL RNA Binding Beads; 4°C • 1.1 mL Lysis/Binding Enhancer; -20°C • 110 μL TURBO DNase; -20°C |
| Isolation Technology | Magnetic Bead |
| Volume di eluizione | 50 μL |
| Tipo di campione | Cells, Plants, Tissue |
| Tipo di prodotto finale | Total RNA |
| Compatibilità ad alta produttività | High-throughput Compatible |
| Da utilizzare con (apparecchiatura) | KingFisher™ Duo Prime, KingFisher™ Flex, Automated Liquid Handling Systems |
| Da utilizzare con (applicazione) | RT-PCR, qPCR, cDNA library construction, NGS, microarray analysis, blot hybridization, Northern blotting, in vitro translation, nuclease protection assays, nucleic acid labeling |
| Quantità | 96 Preps |
| Shipping Condition | Box 1: Dry Ice Box 2: Room Temperature |
| Vedi altri risultati |
Sicurezza e movimentazione
- MagMAX-96 Total RNA Isolation Kit
- Pericolo
- Tossicità acuta Categoria 4
- PERICOLO A LUNGO TERMINE PER L'AMBIENTE ACQUATICO Cronico 3
- Lesione oculare grave/irritazione oculare Categoria 2
- Sensibilizzante delle vie respiratorie Categoria 1
- Corrosione/irritazione della pelle Categoria 1C
- Corrosione/irritazione della pelle Categoria 2
- H302-Nocivo se ingerito.
- H314-Provoca gravi ustioni cutanee e gravi lesioni oculari.
- H315-Provoca irritazione cutanea.
- H319-Provoca grave irritazione oculare.
- H334-Può provocare sintomi allergici o asmatici o difficoltà respiratorie se inalato.
- H412-Nocivo per gli organismi acquatici con effetti di lunga durata.
- P260-Non respirare la polvere/i fumi/i gas/la nebbia/i vapori/gli aerosol.
- P261-Evitare di respirare la polvere/i fumi/i gas/la nebbia/i vapori/gli aerosol.
- P264-Lavare accuratamente dopo l'uso.
- P270-Non mangiare, né bere, né fumare durante l'uso.
- P273-Non disperdere nell'ambiente.
- P280-Indossare guanti/indumenti protettivi/Proteggere gli occhi/il viso.
- P284-[Quando la ventilazione del locale è insufficiente] indossare un apparecchio di protezione respiratoria.
- P301+P310-IN CASO DI INGESTIONE: contattare immediatamente un CENTRO ANTIVELENI/un medico
- P301+P312-IN CASO DI INGESTIONE accompagnata da malessere: contattare un CENTRO ANTIVELENI/medico
- P301+P330+P331-IN CASO DI INGESTIONE: sciacquare la bocca. NON provocare il vomito.
- P302+P352-IN CASO DI CONTATTO CON LA PELLE: lavare abbondantemente con acqua/.
- P303+P361+P353-IN CASO DI CONTATTO CON LA PELLE (o con i capelli): togliere immediatamente tutti gli indumenti contaminati. Sciacquare la pelle/fare una doccia.
- P304+P340-IN CASO DI INALAZIONE: trasportare l'infortunato all'aria aperta e mantenerlo a riposo in posizione che favorisca la respirazione.
- P305+P351+P338-IN CASO DI CONTATTO CON GLI OCCHI: sciacquare accuratamente per parecchi minuti. Togliere le eventuali lenti a contatto se è agevole farlo. Continuare a sciacquare.
- P310-Contattare immediatamente un CENTRO ANTIVELENI/un medico .
- P330-Sciacquare la bocca.
- P342+P311-In caso di sintomi respiratori: contattare un CENTRO ANTIVELENI/un medico/ .
- P363-Lavare gli indumenti contaminati prima di indossarli nuovamente.
- P501b-Smaltire il prodotto/recipiente in conformità con le disposizioni locali/regionali/nazionali/internazionali.
- MIXTURE LIST-Contain: Proteinase, tritirachium album serine, Thiocyanic acid
For Research Use Only. Not for use in diagnostic procedures.
By clicking Submit, you acknowledge that you may be contacted by Fisher Scientific in regards to the feedback you have provided in this form. We will not share your information for any other purposes. All contact information provided shall also be maintained in accordance with our Privacy Policy.