Filtered Search Results
Cytiva Whatman™ Lens Cleaning Tissue
Provides scratch-free cleaning solutions. Whatman™ Lens Cleaning Tissue safely removes surface moisture and grease.
| Description | Won't damage lenses or optical surfaces, leaves no fibers |
|---|---|
| Product Type | Lens Wipe |
| For Use With (Application) | Safe removal of surface moisture and grease. |
Cytiva Whatman™ Binder-Free Glass Microfiber Filters GF/F Circles
Served as the basis filter for EPA standard for the toxicity characteristic leaching procedure. Whatman™ Binder-Free Glass Microfiber Filters GF/F Circles offers an extremely high loading capacity and flow rate.
| Particle Retention | 0.7 μm |
|---|---|
| Temperature (English) Max. | 932°F |
| Shape | Circle |
| Description | Whatman Grade GF/F filter from Cytiva's business is manufactured from pure borosilicate glass. GF/F offers very fine particle retention and good loading capacity and flow rate. |
| Temperature (Metric) Max | 500°C |
| Grade | Grade GF/F |
| Material | Borosilicate Glass |
| For Use With (Application) | Recommended for DNA binding and purification.Very effective in filtering finely precipitated proteins.Can be used in conjunction with GF/D as a prefilter for the successful clarification of extremely ‘difficult’ biochemical solutions and fluids and nucl |
| Thickness (Metric) | 420 μm |
| Flow Rate | 19 sec./100mL/in.2 |
| Type | Filter for TCLP Test Use |
| Format | Disc |
| Thickness (English) | 0.016 in. |
| Autoclavable | Autoclavable |
| Waterflow Rate | 41 mL/min |
Cytiva Percoll™ Centrifugation Media
For separation of cells, subcellular particles, and larger viruses (down to approx. 70S) under gentle conditions that preserve viability and morphological integrity. Cytiva™ Percoll™ Centrifugation Media Percoll is composed of colloidal silica coated with polyvinylpyrrolidone (PVP).
| Viscosity | 15cP |
|---|---|
| Content And Storage | 4–30°C |
| Form | Liquid |
| Product Type | Centrifugation Media |
| Color | Colorless to Slightly Yellow |
| pH | 8.5 to 9.5 |
| Shelf Life | 5 years |
| For Use With (Application) | Cell Isolation |
| Density | 1.135 g/mL |
| Osmolality | < 25 mOsm/kg |
Cytiva Amersham™ ECL™ Prime Western Blotting Detection Reagent
Enables the use of highly diluted primary and secondary antibodies without reducing sensitivity. Cytiva Lifescience™ Amersham™ ECL™ Prime Western Blotting Detection Reagent produces high signal intensity and sensitivity.
| Sensitivity | ∼1 pg |
|---|---|
| Product Type | ECL Western Blot Detection Reagent |
| For Use With (Application) | Sensitive Quantitative or Confirmatory Western Blot |
Cytiva Whatman™ Benchkote Surface Protector Sheets
Minimize mess and contamination during spills. Whatman™ Benchkote material has a high-quality, smooth, absorbent lab paper layer that soaks up liquid spills. A second laminated polyethylene layer prevents flow-through to the working surface.
| Length (Metric) | 460 mm |
|---|---|
| Product Type | Surface Protector |
| Material | Polyethylene |
| Width (Metric) | 570 mm |
| Dimensions (L x W) | 460 x 570mm |
Cytiva NAP™ Columns, NAP-5
Use for rapid and efficient purification of DNA and oligonucleotides (>10-mer) in less than 15 minutes by gravity flow. Cytiva Life Sciences™ illustra™ NAP™ Columns are disposable columns prepacked with Sephadex™ G-25 DNA Grade
| Includes | Complete step-by-step protocol identifying the fixed volumes needed for equilibration, washing and sample elution |
|---|---|
| Product Type | NAP-5 |
| For Use With (Application) | Rapid and efficient purification of DNA and Oligonucleotides |
Cytiva Superdex™ 200 Increase 10/300 GL Prepacked Tricorn™ Columns
For size exclusion chromatography and analysis of proteins with molecular weights between 10,000 and 600,000. Cytiva Lifescience™ Superdex™ 200 Increase 10/300 GL Prepacked Tricorn™ Columns are designed for small scale preparative purification.
anti-Mouse IgG, peroxidase-linked species-specific whole antibody (from sheep) Secondary Antibody, Cytiva
Highly species-specific anti-Mouse IgG. Cytiva Lifescience™ anti-Mouse IgG, peroxidase-linked species-specific whole antibody (from sheep) Secondary Antibody is designed for applications such as protein blotting, ELISA and immunocytochemistry.
| Antigen | IgG, Whole Molecule |
|---|---|
| Purification Method | Affinity Purified |
| Host Species | Sheep |
| Conjugate | HRP |
| Classification | Monoclonal |
| Isotype | IgG |
| Primary or Secondary | Secondary |
Cytiva HisTrap™ FF Columns: 16 x 25mm
Use for optimized purification of histidine-tagged proteins directly from homogenized, unclarified cells by immobilized metal ion affinity chromatography (IMAC). Cytiva Life Sciences™ HisTrap™ FF Columns: 16 x 25mm is a ready-to-use column, prepacked with precharged Ni Sepharose™ 6 Fast Flow.
| Flow Rate | <20 mL/min. |
|---|---|
| Type | Pre-packed Column |
| Content And Storage | 4°C to 30°C, 20% Ethanol |
| Diameter (English) Inner | 0.6 in. |
| Description | HisTrap FF is a ready-to-use column, prepacked with precharged Ni Sepharose 6 Fast Flow for preparative purification of histidine-tagged recombinant proteins by immobilized metal ion affinity chromatography (IMAC). |
| Max. Operating Pressure | 5 bar (0.5 MPa, 70 psi) |
| pH Range | 3 to 12 |
| Diameter (Metric) Inner | 16 mm |
| Material | Polypropylene |
| Support Type | 6% Cross-linked Agarose |
Cytiva Polypropylene Screw Lid GL45 Kit
Used to secure containers. Cytiva Polypropylene Screw lid GL45 Kit comes with screw lid and cap membrane.
Cytiva Whatman™ Qualitative Grade Plain Circles and Sheets - Grade 3
Used for high precipitate capacity and increased wet strength. Whatman™ Qualitative Grade Plain Circles and Sheets - Grade 3 provide double the thickness of Whatman Grade 1.
| Thickness (Metric) | 390 μm |
|---|---|
| Grade | Grade 3 |
| Material | Cellulose |
| For Use With (Application) | A standard grade filter used in qualitative analytical techniques to determine and identify materials. For use in büchner funnels. |
Cytiva GFX™ PCR DNA and Gel Band Purification Kit
Purify and concentrate PCR products or DNA fragments ranging in size from 50 bp to 10 kb. Cytiva Life Sciences™ illustra™ GFX™ PCR DNA and Gel Band Purification Kit can be used to purify DNA from reaction volumes up to 100μL or agarose gel slices of up to 900mg.
| Includes | GFX™ columns, collection tubes, color-coded bottles of capture Buffer, Wash Buffer, two Elution Buffers |
|---|---|
| Description | Designed for the rapid purification and concentration of PCR products or DNA fragments ranging in size from 50 bp to 10 kb. This kit can be used to purify DNA from reaction volumes up to 100 μl or agarose gel slices up to 900 mg. |
| Product Type | illustra GFX PCR DNA and Gel Band Purification Kit |
| Formulation | Tris HCl and sterile Water |
| Sample Type | Agarose Gel Slices,DNA Solutions,Enzyme Reactions,PCR Mixtures |
| Sample Volume | 50 bp-10 kb |
| Yield | PCR 10 μl elution volume-65%, PCR 50 μl elution volume-82%, 300 mg agarose 10 μl elution volume-57%, 300 mg agarose 50 μl elution volume-91% |
| For Use With (Application) | Isolation and concentration of DNA fragments (50bp to 10kb) from PCR mixtures, DNA-containing Agarose Gel bands, Enzyme-based DNA modifications and restriction digestions |
| Type | pH Indicator Dispenser |
|---|---|
| For Use With (Application) | Routine pH testing |
Cytiva Whatman™ Binder-Free Glass Microfiber Filters, Grade GF/A
Combines high loading capacity with fine particle retention. Whatman™ Binder-Free Glass Microfiber Filters, Grade GF/A are ideal for gravimetric determination of airborne particulates, stack sampling and absorption methods of air pollution monitoring.
| Particle Retention | 1.6 μm |
|---|---|
| Temperature (English) Max. | 932°F |
| Shape | Circle |
| Description | GE’s Whatman Grade GF/A glass microfiber filters feature fine retention. GF/A filters are suitable for water quality parameter measurement and air filtration applications. |
| Temperature (Metric) Max | 500°C |
| Quantity | 100 Pieces |
| Grade | Grade GF/A |
| Material | Borosilicate Glass |
| For Use With (Application) | Used for high-efficiency general purpose laboratory filtration, including water pollution monitoring of effluents, for filtration of water, foodstuff analyses, protein filtration, and radioimmunoassay of weak β emitters. |
| Thickness (Metric) | 260 μm |
| Flow Rate | 13 sec./100mL |
| Type | Fine Retention Filter |
| Format | Disc |
| Thickness (English) | 0.01 in. |
| Waterflow Rate | 143 mL/min |
Cytiva Whatman™ Qualitative Filter Paper: Grade 4 Circles
Filters and retains coarse particles for monitoring air pollution. Whatman™ Qualitative Filter Paper: Grade 4 Circles are used when high flow rates in air pollution monitoring are required and the collection of fine particles is not critical.
| Thickness (Metric) | 210 μm |
|---|---|
| Pore Size | 20 to 25 μm |
| Flow Rate | Fast |
| Particle Retention | 25 μm |
| Format | Disc |
| Grade | Grade 4 |
| Material | Cellulose |
| Porosity | Medium |
| Filtration Speed | 37 sec. |